Home›Products›Ridge vents

Ridge vents for livestock buildings.

Ridge vents provide natural extraction of warm air and moisture from the space under the roof and at the same time bring daylight into the livestock building. We manufacture them in two versions - as electrically operated double-leaf vents with the option of stepless adjustment of the opening and connection to the HAZE weather station, or as static vents in GRP or polycarbonate that stay permanently open and provide continuous natural ventilation. We manufacture vents from 0.4 to 4.5 m wide according to the requirements of the specific building. Below you will find detailed information about each version and a comparison between them.

HAZE ridge vent - completed project
Versions in detail

Each version described.

Double-leaf ridge vent with an electric drive - HAZE completed project
Podmyče project
With adjustment

Double-leaf ridge vent - electric drive

The electrically operated double-leaf ridge vent allows stepless adjustment of natural ventilation according to the current conditions in the livestock building. The system can be linked to the HAZE weather station, which automatically opens and closes the vent according to the weather, and it can be fitted with a back-up power supply to keep it running during a power failure. We manufacture the opening width in the range from 1500 to 1800 mm. The infill can be curtain or polycarbonate. The curtain version is standard in livestock buildings, while the polycarbonate infill is suitable above all for milking parlours and other buildings with higher demands on thermal insulation and natural daylight.

ControlYes, stepless opening and closing
OperationElectric drive, connection to the HAZE weather station
InfillCurtain or polycarbonate
Available widths1.5 - 1.8 m
Max. length - curtain infill140 m
Max. length - polycarbonate infill100 m
HAZE saddle ridge cover
Maintenance-free design

Ridge vent without adjustment - saddle ridge cover

A top ridge cover at the same pitch as the roof. The cover is made of polycarbonate with a sheet metal side deflector and the system is maintenance-free. It provides natural ventilation and daylight in the livestock building.

ControlNo, not adjustable
OperationNone, permanent ventilation
InfillPolycarbonate
Available widths1 - 3 m
Max. length100 m
Ridge vent without adjustment, HAZE completed project
Permanent ventilation

Ridge vent without adjustment - polycarbonate arch

This ridge vent stays permanently open and provides continuous extraction of warm air and moisture from the livestock building together with a supply of daylight. The structure is a hot-dip galvanised steel frame and the infill is a self-supporting polycarbonate arch. This type of vent is available for opening widths from 1.5 m to 4.5 m. The polycarbonate infill gives better thermal insulation properties and higher daylight transmission.

ControlNo, not adjustable
OperationNone, permanent ventilation
InfillPolycarbonate
Available widths1.5 - 4.5 m
Max. length100 m
Ridge vent without adjustment - GRP arch, HAZE completed project
Permanent ventilation

Ridge vent without adjustment - GRP

This ridge vent stays permanently open and provides continuous extraction of warm air and moisture from the livestock building together with a supply of daylight. The structure is a hot-dip galvanised steel frame and the infill is made of GRP. This type of vent is available for opening widths from 0.42 m to 1.4 m. The GRP infill offers high strength, a long service life, good thermal insulation properties and high daylight transmission.

ControlNo, not adjustable
OperationNone, permanent ventilation
InfillGRP
Available widths0.42 - 1.4 m
Max. length100 m
Sheet metal work for HAZE ridge vents
Accessory for ridge vents

Sheet metal work and additional products

For ridge vents we supply metal flashing, which protects the structure against rainwater ingress. The need for flashing is always assessed individually according to the structure and specifications of the particular building. We offer the flashing with or without a sealing profile, in colours from the RAL colour chart.

VersionWith or without a sealing profile
ColoursFrom the RAL colour chart
When it is requiredAssessed individually according to the structure and specifications of the building
How to choose a version

Which ventilation to choose.

What matters is whether you want stepless adjustment of the ventilation, the width of the vent and the pitch of the roof. For each version you can see the parameter and what it is suitable for.

  • Double-leaf ridge vent - electric drive Stepless control. Double-leaf ridge vent with an electric drive and weather station, curtain or polycarbonate infill.
    Version
    Double-leaf, adjustable
    Parameter
    Width 1500 - 1800 mm
    Suitable for
    Livestock buildings and milking parlours
    Details →
  • Ridge vent without adjustment - saddle ridge cover Maintenance-free. A top ridge cover following the roof pitch, polycarbonate with a sheet metal deflector, maintenance-free.
    Version
    Ridge cover
    Parameter
    Width 1 - 3 m
    Suitable for
    Natural ventilation and light
    Details →
  • Ridge vent without adjustment - polycarbonate arch More light and insulation. A permanently open, self-supporting polycarbonate arch for wider ridges.
    Version
    Arch without damper
    Parameter
    Width 1.5 - 4.5 m
    Suitable for
    Livestock buildings, collecting yards, storage buildings
    Details →
  • Ridge vent without adjustment - GRP Narrow ridges. A permanently open GRP ridge vent for the smallest opening widths, with high strength and a long service life.
    Version
    Arch without damper
    Parameter
    Width 0.42 - 1.4 m
    Suitable for
    Livestock buildings, collecting yards, storage buildings
    Details →
  • Sheet metal work and additional products Protection against water ingress. Metal flashing against rainwater ingress, with or without a sealing profile, in RAL colours.
    Version
    Accessory
    Parameter
    Individual assessment
    Suitable for
    Protection against water ingress
    Details →
No-obligation enquiry

Fill in the form and we will get back to you by the next working day.

We use the details from this form to handle your enquiry. If you have consented to advertising, we pass your e-mail and phone number to Google in hashed form to measure our ads. More in our privacy policy.

Frequently asked questions

What you ask most often.

What is the difference between an adjustable ridge vent and one without a damper?

The adjustable double-leaf ridge vent can be opened and closed steplessly by an electric drive and linked to the weather station, so it responds to the weather. Arches without a damper cannot be closed - they provide permanent ventilation and daylight in the livestock building, and they have a simpler structure and a lower price.

Should I choose GRP or polycarbonate?

GRP is the least expensive option but it insulates less well. Polycarbonate holds heat better, has high light transmission and prevents the livestock building from overheating. We offer both variants for the arches without a damper; for the adjustable double-leaf ridge vent you choose between curtain and polycarbonate.

What vent width can you supply?

From 0.4 to 4.5 m depending on the variant. Smaller arches are for narrower ridges; self-supporting arches and sheet polycarbonate reach up to 4.5 m. The adjustable double-leaf ridge vent has an opening width of 1500 - 1800 mm.

When is flashing needed?

We always assess the need for flashing individually according to the structure and specifications of the particular building. Metal flashing protects the structure against rainwater ingress and we supply it with or without a sealing profile, in colours from the RAL colour chart.

Can the ridge vent be connected to automatic control?

Yes. The adjustable double-leaf ridge vent is operated by an electric drive, is linked to the HAZE weather station and can be integrated into the automatic control of the livestock building. It can be fitted with a back-up power supply so that it works during a power failure.

Which operations are the ridge vents suitable for?

For cattle, horse, sheep and goat housing, collecting yards and milking parlours, and also for wastewater treatment plants, storage buildings and industrial buildings. We design the specific version according to the building and the operation.